Electronic Rack Equipment
PRODUCTS
OPW Engineered Systems supplies a complete line of Civacon brand loading rack monitors and electronic rack equipment used in loading and unloading operations. The monitors can detect the type of sensor in the transport, the state of liquid in the tank, an overfill situation, and/or verify the grounding condition.
RM140W Overfill Protection Rack Monitor
Overfill protection and grounding monitor for truck or rail loading in petrochemical applications. Built to function with all probes designed to the API code: API RP 1004 and the EU Standard EN13922, the RM140W Series is the world’s most flexible and adaptable monitor.
The RM140W provides a fail-safe, state-of-the-art overfill protection, and grounding monitoring system that is compatible with all commonly used overfill protection and grounding systems.
Features/Benefits
Features/Benefits
Specifications
Electrical
Power | 240V Operation | 110V Operation |
---|---|---|
Minimum Input Voltage | 185VAC | 85VAC |
Maximum Input Voltage | 275VAC | 135VAC |
In-rush Current | 2.2A | 2.3A |
Maximum Current | 400mA | 400mA |
Normal Power Consumption | 8.6W (No probe) 20W (8x 2-wire probes) | 8.6W (No probe) 20W (8x 2-wire probes) |
Mains Power Fuse Rating | 250V, 400mA anti-surge 1500A Breaking Capacity | 250V 400mA anti-surge 1500A Breaking Capacity |
Intrinsically Safe Signals
Nominal Voltage | 10.5V, 13.02V Max |
Nominal Current | 116mA, 121mA Max |
Relay Outputs | Overfill Monitoring Relay |
Relay Contacts | Common, Normally Open, Normally Closed |
Maximum Contact Voltage | 250VAC |
Maximum Contact Load | 5A (resistive), 2.5A (inductive) |
Relay Fuse Rating | 250V @ 5A anti-surge |
Mechanical
Standard | Metric | |
---|---|---|
Width | 12.8" | 324mm |
Height | 13.4" | 340mm |
Depth | 13.4" | 170mm |
Weight | 36.37 lb | 16.5 kg |
Material | Aluminium Housing Base and Cover, Laminated Glass Window |
Optic Rack Monitor Model 8130 for Bottom & Top Loading
Well-suited for bottom-loading applications with vehicles outfitted with Optic sensors, and also suited for overfill protection while top-loading railcars or tank trucks. Generates a unique, pulsed — and intrinsically safe — electrical signal that is transmitted to the sensors via a coiled cord and optic-format plug. When sensors on the transport are dry a signal is returned to the monitor. If the signal meets pre-determined characteristics the monitor goes to a “permissive” state, which changes the status light on the front of the 8100 Series Optic Rack Monitor from red (“non-permissive”) to green (“permissive”).
If the sensor becomes wet, the relay is opened and the status light changes from green to red (non-permissive), shutting down the loading process. The Model 8130 Optic Monitor with Ground Verification includes displayed status of the optic sensor (“permissive” or “non-permissive”) and mode of operation. If the bypass mode is activated the green and red status lights will flash alternately. If the monitor does not receive a proper ground verification signal, the red status light will flash repeatedly, shutting down the loading process. Ground verification cannot be bypassed.
Features/Benefits
Features/Benefits
Order Guide
Order Guide
- Monitors
- 8130-8130 Optic rack monitor with indicator lamps, integrated ground verification
- 8150-8150 Optic rack monitor with indicator lamps, ground verification and “Smart Remote” tamper-resistant keyed bypass switch
- Optic Plug & Cords
- 7120-7120, Optic plug with 30’ 10-conductor coiled cord and 7-pin breakaway plug
- 7100SR-7100, Optic plug with 30’ 6-conductor blue coiled cord for Scully replacement
- 7120SR-7120, Optic plug with 30’ 6-conductor blue coiled cord for Scully replacement and 7-pin breakaway plug
- 7190S-0020, 7100-7100 Optic plug with 30’ coiled cord and 7500-7500 junction box
- 7120-7120 Optic Breakaway Plug with 30’ coiled cord and 7540-7540 breakaway junction box
- Grounding Cable & Clamps
- 7720-7720, Ground Verification Clamp with 40’ straight cord
- 7720-COIL, Ground Verification Clamp with 30’ coiled cord
- 7620-7620, Ground Verification Plug & Cord Set for dual ball application with 30’ straight cord
- 7620-COIL, Ground Verification Plug & Cord Set for dual ball application with 30’ coiled cord
- Junction Boxes
- 7500-7500, Junction Box for Optic, Thermistor and Ground verification Plug & Cord Sets (Non-Breakaway)
- 7540-7540, Junction Box with 7-pin socket for Cane Probes or Breakaway Optic Plug & Cord Sets
- 7540-8X30, Junction Box with 7-pin socket for Breakaway Optic Plug & Cord Sets, Includes bypass connection for 8130 Optic Rack Monitor (Does NOT include BCU-2)
- Options
- 8150-120, 8130-120 Optic Rack Monitor with Ground Verification, Red/Green Indicator Lights, Includes 7560-7560 Junction Box and one BCU-2 Bypass Control Unit
- 7150-7150, Optic Plug Hanger
- 7560-7560, Junction Box with bypass connection for 8150 Optic Rack Monitor (Does not include BCU-2 Bypass Control Unit)
- BCU-2, Bypass Control Unit for 8150 Optic Rack Monitor (7560-7560 or 7540-8X30 Junction Box required)
- 1386-1386, Opti/Therm Rack Monitor Tester
Ground Verification Monitor Model 8030 for Grounding Only Applications
Civacon’s Ground Verification Monitor (Model 8030) visually confirms a ground connection between the transport and the loading terminal, giving you peace of mind and more importantly, safety. The Civacon model 8030, Ground Verification Monitor uses technology that is compatible with transport ground systems used today. The monitor has a 5 amperage, 240 volt relay output for control of terminal automation systems (T.A.S.) or pump control devices when used as a stand-alone system. The monitor is equipped with green and red lamps for visual status indication. When a proper ground signal is present the green lamp will light and a permissive signal will allow the load rack to be operational. If the ground is lost, the red lamp will come on indicating a non-permissive state and shut down the loading operation.
Features/Benefits
Features/Benefits
Order Guide
Order Guide
- Monitors
- 8030-120- Ground Monitor with Red/Green Status Lights, 120 Volt
- 8030-240- Ground Monitor with Red/Green Status Lights, 240 Volt
- Grounding Cable & Clamps
- 7720-7720, Ground Verification Clamp with 40’ straight cord
- 7720-COIL, Ground Verification Clamp with 30’ coiled cord
- 7620-7620, Ground Verification Plug & Cord Set for dual ball application with 30’ straight cord
- 7620-COIL, Ground Verification Plug & Cord Set for dual ball application with 30’ coiled cord
- Junction Boxes
- 7500-7500, Junction Box for Optic, Thermistor and Ground verification Plug & Cord Sets (Non-Breakaway)
- Options
- 7560-7560, Junction Box with bypass connection for 8150 Optic Rack Monitor (Does not include BCU-2 Bypass Control Unit)
- BCU-2, Bypass Control Unit for 8150 Optic Rack Monitor (7560-7560 or 7540-8X30 Junction Box required)
Plug & Cord Sets
Civacon Plug & Cord sets for your your terminal loading systems offer safety, reliability, corrosion resistance and long product life-cycle. They are also very easy to use and handle.
Features/Benefits
Features/Benefits
Order Guide
Order Guide
- Optic Plug & Cords
- 7100-7100, Optic plug with 30’ 10-conductor coiled cord
- 7120-7120, Optic plug with 30’ 10-conductor coiled cord and 7-pin breakaway plug
- 7100SR-7100, Optic plug with 30’ 6-conductor blue coiled cord for Scully replacement
- 7120SR-7120, Optic plug with 30’ 6-conductor blue coiled cord for Scully replacement and 7-pin breakaway plug
- 7190S-0020, 7100-7100 Optic plug with 30’ coiled cord and 7500-7500 junction box
- 7120-7120 Optic Breakaway Plug with 30’ coiled cord and 7540-7540 breakaway junction box
- Thermistor Plug & Cords
- 7300-7300, Thermistor plug with 30’ 10-conductor coiled cord
- 7300C-7300, Thermistor plug with 30’ 10-conductor coiled cord, CANADA ONLY
- 7300SR-7300, Thermistor plug with 30’ 10-conductor coiled cord for Scully replacement
- 7320-7320, Thermistor plug with 30’ 10-conductor coiled cord and 13-pin breakaway plug
- 7320SR-7320, Thermistor plug with 30’ 10-conductor coiled cord for Scully replacement and 13-pin breakaway plug
- 7390S-0020, 7300-7300 Thermistor Plug with 30’ 10-conductor coiled cord and 7500-7500 Junction box
- 7320-7320 Thermistor Breakaway Plug with 30’ 10-conductor coiled cord, 13-pin breakaway plug and 7510T-7510 Junction box
- 7320SR-7320 Thermistor Breakaway Plug with 30’ 10-conductor coiled cord for Scully replacement, 13-pin breakaway plug and 7510T-7510 Junction box
- Plug & Cord Junction Boxes and Deadman Switch
- 7500-7500, Junction Box for Optic, Thermistor and Ground verification Plug & Cord Sets (Non-Breakaway)
- 7540-7540, Junction Box with 7-pin socket for Cane Probes or Breakaway Optic Plug & Cord Sets
- 7510T-7510, Junction Box with 13-pin socket for Breakaway Thermistor Plug & Cord Sets
Automatic Switching Scully Replacement Chassis Model 8460SRC
Civacon’s Opti-Therm 8460SRC is a direct replacement chassis for upgrading Scully ST-6 or BICLOPS® rack controlmonitors. The chassis provides the added benefits of Civacon Opti-Therm technology – Automatic SwitchingandInternal Ground Verification for API compatible Optic and Thermistor technology all in one box. Installation requires simple hand tools and typically takes less than an hour.
Features/Benefits
Features/Benefits
Optic Cane Probes
Civacon Cane Probes provide a portable and flexible solution for meeting overfill requirements, with a universal clamp that has been designed to easily and securely attach to petroleum or chemical manholes, making it the ideal solution when a permanent sensor cannot be affixed to a tank or railcar.
Features/Benefits
Features/Benefits
Library
Specifications
- Level Repeatability:Â + 1/16 inch
- Electrical Connections:Â Industry standard 7-pin connector
- Materials: Stainless Steel, Teflon® seals, Glass Prism
- Temp. Range: -40°F to 158°F (-40°C to 70°C)
- Installation Information:Â Provided with the probe. Can also be accessed and downloaded via website.